Providing you the best range of notifier fsp-951 smoke detectors, bosch fap-425-o-smoke detector, addressable bosch smoke detector, optical smoke detector, edward siga-pd + siga-sb smoke detectors and bosch smoke detector with effective & timely delivery.
2 mA (one communication every 5 seconds with red LED solid on)
Weight
95 Gram
Operating Temp.
32 Degree F Or 50 Degree C
Operating Voltage
30 VDC
Shape
Round
Humidity
93% Relative Humidity, Non-condensing
FSP-951 and FSP-951-IV Intelligent Photoelectric Smoke Sensors SPECIFICATIONS Operating Voltage Range: 15 to 32 VDC Operating Current @ 24 VDC: 200 uA (one communication every 5 seconds with green LED blink on communication) Maximum Alarm Current: 2 mA @ 24 VDC (one communication every 5 seconds with red LED solid on) Maximum Current: 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED solid on) Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing Operating Temperature Range: 32°F to 122°F (0°C to 50°C) Air Velocity: 0 to 4000 ft./min. (0 to 1219.2 m/min.) Height: 2.0˝ (51 mm) installed in B300-6 Base Diameter: 6.2˝ (156 mm) installed in B300-6 Base; 4.1˝ (104 mm) installed in B501 Base Weight: 3.4 oz. (95 g) Isolator Load Rating: 0.0063* *Please refer to your isolator base/module manual for isolator calculation instructions.
u Highly reliable and accurate thanks to Intelligent Signal Processing (ISP) u Earliest detection of lightest smoke with dualoptical versions u Monitors environment for electromagnetic influence for fast root-cause analysis u Automatic and manual address setting
The automatic fire detectors of the AVENAR detector 4000 series feature a superb accuracy and swiftness in detection. The range includes versions with rotaries, manually and automatically addressable, and versions without rotaries for automatic address setting. Multiple-criteria detectors can support, if single sensors are not sufficient. They have highest stability against deceptive phenomena and response to a broad range of fires. The versions with two optical sensors (dual‑optical) detect the lightest smoke. The versions with heat sensor detect fires with rapid temperature increase or with a maximum temperature value.
Highly reliable and accurate thanks to Intelligent Signal Processing (ISP) u Earliest detection of lightest smoke with dualoptical versions (Dual-Ray technology) u Monitors environment for electromagnetic influence for fast root-cause analysis u Automatic and manual address setting
IP41 , IP43 With Detector Base And FAA-420-Seal Or MSC 420
The automatic fire detectors of the AVENAR detector 4000 series feature a superb accuracy and swiftness in detection. The range includes versions with rotaries, manually and automatically addressable, and versions without rotaries for automatic address setting
Optical sensor (smoke sensor) The optical sensor uses the scattered-light method. An LED transmits light to the measuring chamber, where it is absorbed by the labyrinth structure. In the event of a fire, smoke enters the measuring chamber and the smoke particles scatter the light from the LED. The amount of light hitting the photo diode is converted into a proportional electrical signal. The dual-optical versions use two optical sensors with different wavelengths. The Dual-Ray technology works with an infrared and a blue LED so that lightest smoke is detected fast and reliably (TF1 and TF9 detection).
Intelligent Smoke Detector SIGA-PD Overview The Signature Series SIGA-PD optical smoke detector brings advanced sensing technology to a practical design that increases efficiency, saves installation time, cuts costs, and extends life safety and property protection capabilities. Continuous self-diagnostics ensure reliability over the long-haul, while environmental compensation helps reduce maintenance costs. Standard Features Note: Some features described here may not be supported by all control systems. Check your control panel’s Installation and Operation Guide for details. • Next Generation Optical Smoke Sensing Technology • Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration • Uses Existing Wiring • Automatic Device Mapping • Up To 250 Total Signature Addresses Per Loop • Two Levels of Environmental Compensation • Two Levels of Dirty Detector Warning • Twenty Pre-Alarm Settings • Five Sensitivity Settings • Non-Volatile Memory • Electronic Addressing • Identification of Dirty or Defective Detectors • Automatic Day/Night Sensitivity Adjustment • Bicolor (Green/Red) Status Led • Standard, Relay, Fault Isolator, and Audible Mounting Bases • Sensor Markings Provide Easy Testing Identification
Optical sensor (smoke sensor) The optical sensor uses the scattered-light method. An LED transmits light to the measuring chamber, where it is absorbed by the labyrinth structure. In the event of a fire, smoke enters the measuring chamber and the smoke particles scatter the light from the LED. The amount of light hitting the photo diode is converted into a proportional electrical signal. The dual-optical versions use two optical sensors with different wavelengths.
Intelligent Multisensor Smoke and Heat Detector SIGA-OSHD Overview The Signature Optica Series SIGA-OSHD smoke detector brings advanced optical sensing technology to a practical design that increases efficiency, saves installation time, cuts costs, and extends life safety and property protection capabilities. Continuous self-diagnostics ensure reliability over the long-haul, while environmental compensation helps reduce maintenance costs. The SIGA-OSHD provides an optical smoke sensor and a rate-of-rise heat sensor with a fixed temperature setting. Together these sensors efficiently detect smoldering fires, as well as fast flaming fires. Standard Features • Multi-criteria optical smoke sensing technology • Integrates optical smoke with rate-of-rise heat sensing • Wide 0.5 to 4.36 %/ft. (1.6 to 13.6 %/m) smoke obscuration • Integrated nuisance rejection reducing unwanted alarms from general cooking particulates • Uses existing wiring • Listed to UL 268 7th edition • Automatic device mapping • Sensor Markings Provide Easy Testing Identification • Up To 250 Total Signature Addresses Per Loop • Two levels of environmental compensation • Two levels of dirty detector warning • Twenty pre-alarm settings • Five sensitivity settings • Non-volatile memory • Electronic addressing • Automatic day/night sensitivity adjustment • Bicolor (green/red) status LED • Standard, relay, fault isolator, and audible mounting bases